Foreword
Appropriate use
The mains chokes of the series “AX2090-ND50“ are exclusively intended for application in the control cabinet as
power supply unit of the AX5000. The chokes are installed together with the servo drive as components in electrical
systems and machinery and may only be used in this way.
Safety
Safety rules
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for
safety, including all the relevant laws, regulations and guidelines
DANGER
Serious risk of injury through electric shock!
Even when the AX5000 is disconnected from the mains voltage, dangerous voltage continues to be
present at the "X02" terminals of the DC link: AX5160/AX5172 = 15 min., AX5190/AX5191 = 30 min. and
AX5192/AX5193 = 45min.. Never touch the terminals within this period.
Risk of injury!
Electronic equipment is not fail-safe. The machine manufacturer is responsible for ensuring that the
connected motors and the machine are brought into a safe state in the event of a fault in the drive system.
Personnel qualification
This description is only intended for trained specialists in control, automation and drive engineering who are familiar
with the applicable national standards. Knowledge of machine safety legislation is compulsory.
Technical data
45 (with power reduction 60)
15%...95%, Condensation not permitted
Permissible contamination
Mounting height
1000 (with power reduction 4000)
(6% / 1000m)