Technical Data
8 Technical Data
Risk of explosion!
Danger
Do not use the Control Panel in areas of explosive hazard!
Pixel errors
Note
Pixel errors in the TFT display are production-caused and represent no complaint-
reason!
Anomalies of the Touchscreen
Note
Anomalies of the touchscreen sensor are production-caused and represent no
complaint-reason!
Product name CP29xx
Dimensions (B x H x T) See chapter Assembly dimensions
Weight CP2907: 1.46 kg CP2918: 5.10 kg
CP2912: 2.95 kg CP2919: 5.36 kg
CP2915: 3.64 kg CP2921: 5.90 kg
CP2916: 4.22 kg CP2924: 7.18 kg
Supply voltage 24 V
DC
(20.4 – 28.8 V
DC
)
Power consumption CP2907-0000: max. 12 W CP2918-0000: max. 25 W
CP2912-0000: max. 16 W CP2919-0000: max. 25 W
CP2915-0000: max. 20 W CP2921-0000: max. 35 W
CP2916-0000: max. 22 W CP2924-0000: max. 45 W
UL-compliance
(in progress)
Using a power supply class 2 or
Fuse protection with 4 A, according to UL 60950.2
chapter 2.5, table 2C
Interfaces
USB 3.0 input for the direct connection to a standard USB output of
a PC with distances of up to 3 m
2-port USB 3.0 socket inside the Control Panel backplane, for
USB-E 2.0 limited to USB 2.0
Integrated DVI/USB extension
technology
DVI-E and USB-E 2.0 enable remote panel operation at a distance
of up to 50 m from the PC
USB-E 2.0 transmits USB 2.0 with 480 Mbit/s
DVI-E input is compatible to the standard DVI output of a PC
Protection class Front side IP65, rear side IP20
Shock resistance
(Sinusoidal vibration)
EN 60068-2-6: 10 to 58 Hz: 0.035 mm
58 to 500 Hz: 0.5 G (~ 5 m/ s
2
)
Shock resistance (Shock) EN 60068-2-27: 5 G (~ 50 m/ s
2
), duration: 30 ms
EMC compatibility Resistance to interference conforms to EN 61000-6-2
EMC compatibility Emission of interference conforms to EN 61000-6-4
Permissible ambient temperature 0°C to +55°C (operation ); CP2924: 0°C to +50°C (operation)
-25°C to +65°C (transport/ storage)
Permissible relative humidity to 95%, no condensation
Transport and storage The same values for atmospheric humidity and shock resistance are
to be observed during transport and storage as in operation. Suitable
packaging of the Panel PC can improve the resistance to impact
during transport.
Certifications CE; UL in progress