Product description
AX5805 43
Parameters for axis 1
Index Name Description Sub-
index
Unit Default
value
0x6651 t_SS1 :001 Maximum time until the activation of the
STO safety function
01 10ms 0x0000
0x6651 t_SS1 :002 Maximum time until the activation of the
STO safety function
02 10ms 0x0000
0x6651 t_SS1 :003 Maximum time until the activation of the
STO safety function
03 10ms 0x0000
0x6651 t_SS1 :004 Maximum time until the activation of the
STO safety function
04 10ms 0x0000
0x6651 t_SS1 :005 Maximum time until the activation of the
STO safety function
05 10ms 0x0000
0x6651 t_SS1 :006 Maximum time until the activation of the
STO safety function
06 10ms 0x0000
0x6651 t_SS1 :007 Maximum time until the activation of the
STO safety function
07 10ms 0x0000
0x6651 t_SS1 :008 Maximum time until the activation of the
STO safety function
08 10ms 0x0000
0x6653 n_Zero_SS
1 32 Bit
:001
Speed window for SS1_1 01 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:002
Speed window for SS1_2 02 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:003
Speed window for SS1_3 03 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:004
Speed window for SS1_4 04 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:005
Speed window for SS1_5 05 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:006
Speed window for SS1_6 06 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:007
Speed window for SS1_7 07 Increments
per ms
0x00000000
0x6653 n_Zero_SS
1 32 Bit
:008
Speed window for SS1_8 08 Increments
per ms
0x00000000
0x6654 t_L SS1
:001
Minimum time until the activation of the
STO safety function, if the speed is
within the window
01 1ms 0x0000
0x6654 t_L SS1
:002
Minimum time until the activation of the
STO safety function, if the speed is
within the window
02 1ms 0x0000
0x6654 t_L SS1
:003
Minimum time until the activation of the
STO safety function, if the speed is
within the window
03 1ms 0x0000