DocumentationKL3681,KS3681MultimeterTerminals2.0.020150401VersionDate
ProductoverviewFilterThebuiltinfilteraveragesthevaluesforthelasthalfsecond.Ifthemeasuringrangeischangedthefilterisreset.Thefilt
Productoverview2.4 ProcessdataCalculationofprocessdataTheprocessdataarecalculatedinuptosevenstepsbetweenreadingoftheADCandthepro
ProductoverviewDesignation Meaning Register Designation Meaning RegisterXADCOutputvalueoftheA/DconverterR0 [}33]YZMeasuredvalueafterADCoffsetc
Productoverview2.5 LEDDisplayFig.2:KL36810000LEDdisplayLED Color MeaningRUN green off KBusdatatransfernotactiveon KBusdatatransferac
Mountingandwiring3 Mountingandwiring3.1 InstallationonmountingrailsWARNINGRiskofelectricshockanddamageofdevice!Bringthebusterminalsy
MountingandwiringDisassemblyFig.4:DisassemblingofterminalEachterminalissecuredbyalockonthemountingrail,whichmustbereleasedfordis
MountingandwiringFig.5:PowercontactonleftsideAttentionPossibledamageofthedeviceNotethat,forreasonsofelectromagneticcompatibility,th
MountingandwiringFig.6:TerminalpointsofKL3681Terminalpoint No. CommentV 1 Terminalpointforvoltagemeasurement(internallyconnectedwithte
Mountingandwiring3.3 ConnectionsystemWARNINGRiskofelectricshockanddamageofdevice!Bringthebusterminalsystemintoasafe,powereddownsta
MountingandwiringConductorcrosssectionsbetween0.08mm2and2.5mm2cancontinuetobeusedwiththeprovenspringforcetechnology.Theoverviewa
MountingandwiringWiringTerminalsforstandardwiringELxxxx/KLxxxxandterminalsforsteadywiringESxxxx/KSxxxxFig.10:Mountingacableonate
MountingandwiringShieldingNoteShieldingAnalogsensorsandactorsshouldalwaysbeconnectedwithshielded,twistedpairedwires.KL3681,KS3681 21Ver
KS2000Configurationsoftware4 KS2000Configurationsoftware4.1 KS2000IntroductionTheKS2000configurationsoftwarepermitsconfiguration,commissi
KS2000ConfigurationsoftwareCommissioningTheKS2000softwarefacilitatescommissioningofmachinecomponentsortheirfieldbusstations:Configuredse
KS2000ConfigurationsoftwareFig.12:ViewoffieldbusstationwithinKS2000ThelefthandKS2000windowdisplaystheterminalsofthefieldbusstation
KS2000Configurationsoftware4.3 RegisterYoucanaccesstheregistersoftheKL3681directlyunderRegister.Themeaningoftheregisterisexplainedi
KS2000ConfigurationsoftwareFig.15:SettingsviaKS2000OperatingmodeWatchdogtimeractive(registerpage0,registerR32.2 [}35])Hereyoucandeac
KS2000ConfigurationsoftwareZeroCompensationIntervalHereyoucanspecifytheintervalforzerocompensation(default:deactivated).Options(registe
Accessfromtheuserprogramm5 Accessfromtheuserprogramm5.1 ProcessimageComplexmappingThefollowing9bytesaretransferredbidirectionallybet
AccessfromtheuserprogrammBit Name DescriptionCB.7 RegAccess 0binRegistercommunicationoff(processdatamode)CB.6 R/W 0binReadaccess1binWriteac
TableofcontentsTableofcontents1 Foreword ...
AccessfromtheuserprogrammBit Name DescriptionCB.7 RegAccess 1binRegistercommunicationswitchedonCB.6 R/W 0binReadaccess1binWriteaccessCB.5to
Accessfromtheuserprogramm5.3 RegisteroverviewAllregisterscanbereadorwrittenviaregister communication [}38].RegistersR0toR31(directa
AccessfromtheuserprogrammRegisterno. Comment Defaultvalue R/W MemoryR32 [}35]Featureregister 0x2804 10244decR/W SEEPROMR33 [}36]ZeroCompInt
Accessfromtheuserprogramm5.4 RegisterdescriptionThefollowingregistersareusedforparameterizationoftheKL3681.Theycanbereadorwritten
AccessfromtheuserprogrammR9:FirmwareversionRegisterR9containstheASCIIcodingoftheterminal'sfirmwarerevisionlevel,e.g.0x3141(1A
Accessfromtheuserprogramm• Ifyouwritevaluesintotheuserregistersandhavepreviouslyenteredtheusercodeword(0x1235)inthecodewordreg
AccessfromtheuserprogrammR33:ZeroCompIntervalR36:Userscaling,measuringrange300mVDC,offset(Default:0x0000)R37:Userscaling,measuringr
AccessfromtheuserprogrammR50:Userscaling,measuringrange300VAC,offset(Default:0x0000)R51:Userscaling,measuringrange300VAC,gain(Defau
AccessfromtheuserprogrammR32toR35:InternalcalibrationdataTheseregisterscontaininternalcalibrationdataandmustnotbechangedbytheuse
Accessfromtheuserprogramm• Theoutputdataword(Byte1andByte2)containsthecodeword0x1235)todeactivatethewriteprotection.Byte0:Statu
Foreword1 Foreword1.1 NotesonthedocumentationThisdescriptionisonlyintendedfortheuseoftrainedspecialistsincontrolandautomationenginee
Accessfromtheuserprogramm• IntheStatusByte,theterminalreturnsavalue,thatdiffersonlyatbit0.6fromthevalueoftheoftheControlByte
Appendix6 Appendix6.1 AccessoriesFuseSparefusesareavailableasaccessories.TheupperofthetwobuiltinfusesintheEL3681isdesignatedasaspa
Appendix6.2 SupportandServiceBeckhoffandtheirpartnersaroundtheworldoffercomprehensivesupportandservice,makingavailablefastandcompeten
TableoffiguresTableoffiguresFig.1 KL36810000 ...
Foreword1.2 SafetyinstructionsSafetyregulationsPleasenotethefollowingsafetyinstructionsandexplanations!Productspecificsafetyinstructionsc
Foreword1.3 DocumentationIssueStatusVersion Comment2.0.0 • migration(completeDocument)• LEDDisplay:meaningofKbusrunledexchanged(off/on)1
Productoverview2 Productoverview2.1 IntroductionFig.1:KL36810000DigitalMultimeterTerminalTheKL3681BusTerminalenablesmeasurementofcurrent
Productoverview2.2 TechnicaldataTechnicaldata KL3681 KS3681Numberofinputs 1,voltageorcurrent(1A/10A)Technology digitalmultimeterwithau
Productoverview• AC/DCvoltagemeasurement,automaticrangeselection:“Autorange”orspecifiedviathecontrollerMeasurementranges:300mV,3V,30
Comments to this Manuals