EBUS/LVDS Interface
Slave Controller – ET1100 Hardware Description III-47
5 EBUS/LVDS Interface
For details about the ESC EBUS Interface refer to Section I.
5.1 EBUS Interface Signals
The EBUS interface of the ET1100 has the following signals:
EtherCAT
device
EBUS-TX-
EBUS-TX+
EBUS-RX+
EBUS-RX-
RBIAS
Figure 8: EBUS Interface Signals
Table 52: EBUS Interface signals
EBUS/LVDS transmit signals
EBUS/LVDS receive signals
BIAS resistor for EBUS-TX current adjustment
NOTE: An external LVDS termination with an impedance of 100 Ω between EBUS-RX+ and EBUS-RX- is
necessary for EBUS ports. EBUS-RX+ incorporates a pull-down resistor and EBUS-RX- incorporated a pull-up
resistor.