Comissioning/Configuration
Index Name Meaning Datatype Flags Default
8021:0 DIGSafestate
value
UINT8 RO 0x08(8
dec
)
8021:01 Output17 0
bin
DIGSafestate
valuefor
output17=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output17=1
8021:02 Output18 0
bin
DIGSafestate
valuefor
output18=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output18=1
8021:03 Output19 0
bin
DIGSafestate
valuefor
output19=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output19=1
8021:04 Output20 0
bin
DIGSafestate
valuefor
output20=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output20=1
8021:05 Output21 0
bin
DIGSafestate
valuefor
output21=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output21=1
8021:06 Output22 0
bin
DIGSafestate
valuefor
output22=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output22=1
8021:07 Output23 0
bin
DIGSafestate
valuefor
output23=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output23=1
8021:08 Output24 0
bin
DIGSafestate
valuefor
output24=0
BOOLEAN RW 0
bin
1
bin
DIGSafestate
valuefor
output24=1
Furtherobjects
Standardobjects(0x10000x1FFF)
ThestandardobjectsofallEtherCATslaveshavethesamemeaning.